1. WebsitePlanet
  2. >
  3. Glossary
  4. >
  5. Web hosting
  6. >
  7. What is RAID?

What is RAID?

Miguel Amado Written by:
Christine Hoang Reviewed by: Christine Hoang
18 December 2024
RAID stands for Redundant Array of Independent (or Inexpensive) Disks. It’s a data storage virtualization technology that combines multiple physical disk drive components into one or more logical units for improved performance, reliability, and fault tolerance. RAID distributes data across the drives in different ways, referred to as RAID levels, depending on the required levels of redundancy and performance.

Definition of RAID

It can be implemented via software or with a hardware RAID controller. The drives are combined to boost speed and protect your data, achieving faster performance than a single drive could provide, as well as adding redundancy so a single drive failure doesn’t mean total data loss.

In a RAID setup, several physical hard disks are set up to read and write data in an interleaved manner, managed by either dedicated hardware or software. If any disks in the array fail, you can potentially replace them without losing any data stored on the array. It’s this resiliency against drive failure that makes RAID so valuable.

How Does RAID Work?

RAID works by placing data on multiple disks and allowing input/output (I/O) operations to overlap in a balanced way, improving performance. Because the use of multiple disks increases the mean time between failures (MTBF), storing data redundantly also increases fault tolerance.

The array appears to the operating system as a single logical drive. RAID employs the techniques of disk mirroring or disk striping and can use a parity scheme to achieve redundancy:

  • Mirroring: Data is written identically to multiple drives, providing complete redundancy if a drive fails.
  • Striping: Data is split across multiple drives, improving performance as drives can be accessed simultaneously.
  • Parity: Parity bits are calculated and written across the array, allowing for data recovery if a drive fails. The parity bits are distributed across all drives in some implementations.
RAID can be controlled by hardware or software:

  • Hardware RAID: Uses a dedicated hardware controller to manage the array.
  • Software RAID: Implemented via software, often as part of the operating system. It uses the host system’s CPU and memory for RAID operations.
Different RAID levels use these techniques in different ways to balance capacity, performance, and redundancy.

RAID Levels Explained

There are several common RAID levels, each using a different architecture to provide a balance of performance, capacity, and redundancy:

RAID 0 (Striping)

RAID 0 splits data evenly across two or more disks, without parity information, redundancy, or fault tolerance. It offers the best performance but no fault tolerance. If a drive fails, all data in the array is lost. RAID 0 requires a minimum of two disks.

Advantages:

  • Excellent performance
  • 100% storage capacity utilization

Disadvantages:

  • No fault tolerance
  • Higher risk of data loss

RAID 1 (Mirroring)

RAID 1 creates an exact copy (mirror) of a set of data on two or more disks. This provides excellent fault tolerance – if one drive fails, data can still be retrieved from the other. Read performance can be improved since either disk can be read simultaneously. RAID 1 requires a minimum of two disks.

Advantages:

  • Excellent fault tolerance
  • Good read performance
  • Simple to implement

Disadvantages:

  • Reduced storage capacity (50% utilization)
  • Slower write performance

RAID 5 (Striping with Distributed Parity)

RAID 5 uses block-level striping with parity data distributed across all member disks. It provides good performance and fault tolerance. If a drive fails, the parity information allows the data on the failed drive to be reconstructed. RAID 5 requires a minimum of three disks.

Advantages:

  • Good performance
  • Good fault tolerance
  • More efficient storage utilization than RAID 1

Disadvantages:

  • Complex to implement
  • Reduced performance during drive failure and rebuild

RAID 6 (Striping with Double Parity)

RAID 6 extends RAID 5 by adding a second parity scheme, allowing the array to continue functioning even if two disks fail simultaneously. It requires a minimum of four disks.

Advantages:

  • Excellent fault tolerance
  • Continues functioning with two failed drives
  • Well suited for large arrays

Disadvantages:

  • Reduced write performance due to additional parity calculation
  • Higher cost due to extra disk for second parity

RAID 10 (Combining RAID 1 & RAID 0)

RAID 10 (sometimes written RAID 1+0) combines RAID 1 and RAID 0, providing the benefits of both – mirroring and striping. It requires a minimum of four disks.

Advantages:

  • Excellent performance
  • Excellent fault tolerance
  • Faster rebuild time than RAID 5 or 6

Disadvantages:

  • High redundancy cost (50% capacity utilization)
  • Minimum 4 drives required
The choice of RAID level depends on your specific needs and the balance of performance, redundancy, and capacity you require.

RAID vs Backup: What’s the Difference?

While RAID provides fault tolerance and can help prevent data loss due to hardware failure, it’s not a substitute for a regular data backup strategy. RAID protects against physical disk failures, but it doesn’t protect against other causes of data loss such as:

  • User error (accidental file deletion or modification)
  • Software issues or bugs causing data corruption
  • Malware or ransomware attacks
  • Physical disasters like fire, flood, or theft.
A comprehensive backup strategy involves regularly creating copies of your data and storing them in a separate location, ideally offsite. This could be on removable media like external hard drives or tapes, or in the cloud. With proper backups, you can recover your data even if your entire RAID array is lost or destroyed.

Think of RAID as a first line of defense against hardware failure and data loss, but not a complete data protection solution. Combining RAID with regular backups provides the best protection for your critical data.

Setting Up RAID: Hardware vs Software

When setting up RAID, you have two main options: hardware RAID and software RAID. Each has its advantages and disadvantages.

Hardware RAID

Hardware RAID uses a dedicated hardware controller to manage the RAID array. The controller is typically a PCI card installed in the server, or it may be integrated into the server motherboard.

Advantages:

  • Offloads RAID processing from the host CPU
  • Better performance, especially for complex RAID levels
  • Can be used with any operating system
  • More reliable due to dedicated hardware

Disadvantages:

  • More expensive due to the cost of the hardware controller
  • Less flexibility – changing RAID levels or expanding the array may require a controller upgrade
  • Specific to the hardware vendor – moving drives to a different controller may not work

Software RAID

Software RAID is implemented at the operating system level, using the host system’s CPU and memory for RAID operations.

Advantages:

  • Less expensive – no need for dedicated hardware
  • More flexible – can be configured and modified easily
  • Can be used with any compatible hard drives

Disadvantages:

  • Uses host system resources, potentially impacting performance
  • Dependent on the operating system – configuration may not be portable
  • May not support all RAID levels
  • Less reliable – a software issue could impact the entire array
The choice between hardware and software RAID depends on your specific needs, budget, and existing infrastructure. Hardware RAID is generally preferred for mission-critical applications and high-performance needs, while software RAID can be a cost-effective solution for less demanding situations.

RAID Performance Considerations

While RAID can significantly improve performance and fault tolerance, there are several factors to consider:

  • RAID level: Different RAID levels have different performance characteristics. For example, RAID 0 provides the best performance but no redundancy, while RAID 1 provides excellent redundancy but with a write performance penalty.
  • Number and speed of drives: The performance of a RAID array is dependent on the number and speed of the individual drives. More drives can provide higher performance, especially for RAID levels that use striping.
  • Hardware vs software: Hardware RAID generally provides better performance than software RAID, as it offloads the RAID processing from the host CPU.
  • Drive type: The type of drives used (HDD vs SSD, SATA vs SAS, etc.) can significantly impact performance. SSDs provide much faster read and write speeds than traditional hard drives.
  • Array size: Larger RAID arrays can provide higher capacity and potentially higher performance, but they also have longer rebuild times if a drive fails.
  • Controller cache: Hardware RAID controllers often include a cache, which can significantly boost write performance by caching writes before committing them to the drives.
  • Workload: The type of workload (sequential vs random, read-heavy vs write-heavy) can affect RAID performance. Some RAID levels are better suited for certain types of workloads.
Optimizing a RAID array for performance involves balancing these factors based on your specific needs and budget. Proper planning, configuration, and maintenance are key to getting the best performance out of your RAID setup.

RAID Maintenance and Monitoring

Proper maintenance and monitoring are crucial for ensuring the health and performance of your RAID array over time. Here are some key considerations:

Monitoring

Regularly monitor your RAID array for any signs of problems, such as:

  • Drive failures or errors
  • Degraded performance
  • Unusual noise or vibration from drives
  • Overheating
Many hardware RAID controllers and software RAID solutions include monitoring tools that can alert you to potential issues. Setting up automated monitoring and alerts can help you catch problems early before they lead to data loss.

Drive replacement

If a drive in your array fails, replace it as soon as possible to maintain the array’s fault tolerance. The specific procedure for replacing a drive depends on your RAID setup, but generally involves:

  1. Identifying the failed drive
  2. Physically replacing the drive
  3. Rebuilding the array onto the new drive
During the rebuild process, the array may operate at reduced performance and be vulnerable to additional drive failures, so it’s important to have a backup of your data.

Firmware updates

Keep your RAID controller or software up to date with the latest firmware and driver updates. These updates often include performance improvements, bug fixes, and new features.

Capacity planning

As your storage needs grow, you may need to expand your RAID array’s capacity. This could involve adding more drives to the array, replacing existing drives with larger ones, or migrating to a larger array. Plan ahead for capacity growth to avoid running out of space unexpectedly.

Testing and validation

Periodically test your RAID array to ensure it’s functioning correctly. This could involve running diagnostic tools, performing data integrity checks, or even simulating a drive failure to test the array’s fault tolerance.

By proactively monitoring and maintaining your RAID array, you can ensure it continues to provide the performance and reliability your applications and users depend on.

The Future of RAID

As data storage needs continue to grow and evolve, so does RAID technology. Here are some trends and developments shaping the future of RAID:

NVMe and PCIe

NVMe (Non-Volatile Memory Express) is a high-performance interface for SSDs that uses PCIe (Peripheral Component Interconnect Express) to connect directly to the system’s CPU. NVMe RAID arrays can provide extremely high performance, with much lower latency than traditional SATA or SAS based arrays.

Storage Class Memory

Storage Class Memory (SCM) is a new type of non-volatile memory that combines the speed of DRAM with the persistence of flash storage. SCM can potentially replace or augment traditional SSDs in RAID arrays, providing even higher performance and lower latency.

Erasure Coding

Erasure coding is a data protection method that involves breaking data into fragments, expanding and encoding the fragments with redundant data pieces, and storing the fragments across a set of different locations or storage media. It provides similar fault tolerance to traditional RAID, but with more flexibility and scalability.

Software-Defined Storage

Software-defined storage (SDS) decouples the storage software from the underlying hardware, allowing for more flexible and scalable storage infrastructure. SDS can incorporate RAID functionality, but can also offer additional features like data deduplication, compression, and automated tiering.

Cloud RAID

With the growth of cloud computing, some organizations are looking to implement RAID functionality in the cloud. This could involve using RAID within individual cloud instances, or spreading RAID arrays across multiple cloud providers for added redundancy.

As these technologies mature and become more widely adopted, they have the potential to significantly shape the future of RAID and data storage in general. However, the fundamental principles of RAID – using multiple drives to improve performance and fault tolerance – are likely to remain relevant for the foreseeable future.

Summary

RAID is a powerful technology that can significantly improve the performance, reliability, and fault tolerance of your data storage systems. By combining multiple physical drives into a single logical unit, RAID can provide faster data access, protection against drive failures, and more efficient use of storage capacity.

However, RAID is not a panacea for all data storage challenges. It’s important to understand the different RAID levels, their strengths and weaknesses, and how they fit into your overall data protection strategy. RAID should be used in conjunction with regular data backups, proactive monitoring and maintenance, and capacity planning for future growth.

As data storage needs continue to evolve, so does RAID technology. New developments like NVMe, storage class memory, and erasure coding are pushing the boundaries of what’s possible with RAID. But the fundamental principles of using multiple drives for performance and redundancy are likely to remain relevant for the foreseeable future.

Implementing RAID effectively requires careful planning, configuration, and ongoing management. Whether you choose hardware or software RAID, it’s crucial to regularly monitor the health of your array, replace failed drives promptly, keep firmware and drivers updated, and test your setup to ensure it’s functioning as expected.

By understanding and leveraging RAID technology appropriately, you can build data storage systems that are fast, reliable, and resilient – helping ensure that your critical data is always available when you need it.

Rate this Article
4.3 Voted by 3 users
You already voted! Undo
This field is required Maximal length of comment is equal 80000 chars Minimal length of comment is equal 10 chars
Related posts
Show more related posts
We check all user comments within 48 hours to make sure they are from real people like you. We're glad you found this article useful - we would appreciate it if you let more people know about it.
Popup final window
Share this blog post with friends and co-workers right now:
1 1 1

We check all comments within 48 hours to make sure they're from real users like you. In the meantime, you can share your comment with others to let more people know what you think.

Once a month you will receive interesting, insightful tips, tricks, and advice to improve your website performance and reach your digital marketing goals!

So happy you liked it!

Share it with your friends!

1 1 1

Or review us on 1

3475322
50
5000
114310726